How to fix Rinnai code 12
- Make sure every gas valve feeding the heater (at the heater and at the meter) is fully open
- On propane, check that the tank isn't empty
- Check the outside vent terminal for snow, leaves, nests or anything blocking it
- Reset: turn off hot water taps and press ON/OFF on the controller twice
- If the code comes back, call a licensed Rinnai service provider
What 12 means on your Rinnai
Code 12 means the flame was established and then lost. Rinnai's first checks are the same as for code 11: gas on at the heater, meter or tank, and propane in the tank.
What a technician will check: that the igniter and flame rod are tight in their bracket, inlet gas pressure under full load (Rinnai expects no more than about 0.3 in. w.c. drop on natural gas and 0.5 in. on propane with everything firing), and the vent system's joints, fittings and terminal clearances.
An immediate code 12 with no visible flame can also be an electrical short; see code 19.
Likely causes
- Gas turned off at the heater, meter or tank
- Propane tank empty
- Loose or dirty flame rod
- Undersized gas line causing pressure drop
- Venting or clearance problem
Sources
- Rinnai: Troubleshooting Tankless Water Heater Diagnostic Codes (doc. 100000652) manufacturer checked 2026-11-21
Spotted an error on this page? Report it and we'll re-check it against the manual.