Rinnai Sensor & Thermistor Codes (32, 33, 34, 35, 38, 41, 51, 58)

These codes mean a temperature sensor isn't reading correctly: outgoing water, heat exchanger, combustion air, tank, exhaust gas, freeze protection, inlet water or secondary heat exchanger. Rinnai's checks are technician work: wiring, scale on the sensor, and resistance readings. Code 58 is the exception that points to scale inside the secondary heat exchanger, which needs flushing.

Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

32Outgoing Water Temperature Thermistor

The sensor that measures water leaving the heater is reading out of range.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 032 · Confirmed by manufacturer · checked 2026-11-21

33Heat Exchanger Thermistor

The heat exchanger temperature sensor is reading out of range.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 033 · Confirmed by manufacturer · checked 2026-11-21

34Combustion Air (Non-SENSEI) / Lime Detecting (SENSEI RX/CX) Thermistor

The combustion air temperature sensor, or on SENSEI RX/CX the lime (scale) detecting sensor, is reading out of range.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 034 · Confirmed by manufacturer · checked 2026-11-21

35Tank Temperature Sensor

On the RH180 hybrid, the tank temperature sensor is reading out of range.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 035 · Confirmed by manufacturer · checked 2026-11-21

38Exhaust Gas Temperature Sensor

The exhaust temperature sensor is reading out of range.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 038 · Confirmed by manufacturer · checked 2026-11-21

41Freeze Protection Sensor (Outdoor Models)

On outdoor models, the freeze protection sensor is disconnected, shorted or reading out of range. Make sure it isn't covered by insulation.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 041 · Confirmed by manufacturer · checked 2026-11-21

51Inlet Water Temperature Thermistor

The incoming water temperature sensor is reading out of range. The heater may keep running while it flashes 51.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 051 · Confirmed by manufacturer · checked 2026-11-21

58Secondary Heat Exchanger Sensor

Rinnai says this code indicates scale build-up inside the secondary heat exchanger, which needs flushing per the owner's manual.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 058 · Confirmed by manufacturer · checked 2026-11-21