07Circulation Flow Rate Below 2.1 GPM (RH180)
On the RH180 hybrid, circulation flow dropped below 2.1 GPM. Check power, that the water supply is on at 30 PSI or more, and that the pump runs.
- Reset: turn off hot water taps and press ON/OFF on the controller twice
- If the code comes back, call a licensed Rinnai service provider
Also shown as: 007, 7 · Confirmed by manufacturer · checked 2026-11-21
13Combustion (RH180)
On the RH180 hybrid, a combustion problem: venting, combustion air, altitude settings or gas pressure.
- Reset: turn off hot water taps and press ON/OFF on the controller twice
- If the code comes back, call a licensed Rinnai service provider
Also shown as: 013 · Confirmed by manufacturer · checked 2026-11-21
30Flammable Vapor Sensor (RH180)
On the RH180 hybrid, the flammable vapor sensor or its wiring has a fault.
- Reset: turn off hot water taps and press ON/OFF on the controller twice
- If the code comes back, call a licensed Rinnai service provider
Also shown as: 030 · Confirmed by manufacturer · checked 2026-11-21
FEFlammable Vapors Detected (RH180)
The RH180 detected flammable vapors. Make sure no flammable vapors are present before power and gas are restored.
- Reset: turn off hot water taps and press ON/OFF on the controller twice
- If the code comes back, call a licensed Rinnai service provider
Also shown as: — · Confirmed by manufacturer · checked 2026-11-21
Sources
- Rinnai: Troubleshooting Tankless Water Heater Diagnostic Codes (doc. 100000652) manufacturer checked 2026-11-21