How to fix Rinnai code 11
- Make sure every gas valve feeding the heater (at the heater and at the meter) is fully open
- On propane, check that the tank isn't empty
- Check the outside vent terminal for snow, leaves, nests or anything blocking it
- Reset: turn off hot water taps and press ON/OFF on the controller twice
- If the code comes back, call a licensed Rinnai service provider
What 11 means on your Rinnai
Rinnai's first checks for code 11 are simple: every gas valve open, propane in the tank, and air purged from the gas lines. A recently refilled propane tank or new gas work is a common trigger.
If gas is fine, the cause is usually inside the heater: carbon or white deposits on the flame rod, a loose ("floating") flame rod or igniter, or a weak spark.
What a technician will check: inlet gas pressure with every gas appliance on high fire, gas type and gas settings, the spark and spark gap (3.5 mm), cleaning the flame rod and igniter (with a new gasket), the vent system and equivalent length, and the high-altitude setting.
If you smell gas, don't reset the heater. Leave the building and call your gas supplier.
Likely causes
- Gas valve closed or propane tank empty
- Air in the gas line after installation or tank refill
- Low gas pressure or undersized gas line
- Dirty or loose flame rod or igniter
- Venting problem or wrong altitude setting
Sources
- Rinnai: Troubleshooting Tankless Water Heater Diagnostic Codes (doc. 100000652) manufacturer checked 2026-11-21