Rinnai Tankless Water Heater · Non-SENSEI series

79Water Leakage Detected

The leak sensor in the bottom of the cabinet detected water.

Difficulty
Technician
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Rinnai code 79

  1. Turn off the water supply to the heater if you can see water leaking
  2. If the code comes back, call a licensed Rinnai service provider

What 79 means on your Rinnai

Code 79 appears on Non-SENSEI models when the leak detector senses water inside the cabinet.

What a technician will check: the heat exchanger and internal piping for leaks, water pooled on the bottom pan (dried out and the sensor cleaned), and the sensor itself. If the heater runs with the sensor unplugged and no water is found, the sensor is replaced.

A leaking heat exchanger can be a warranty item, so have it diagnosed before replacing parts.

Likely causes

  • Leak from the heat exchanger or internal piping
  • Water pooled on the bottom pan
  • Faulty leak sensor or wiring

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.