Rinnai Tankless Water Heater · SENSEI series · SENSEI RX/CX series · Non-SENSEI series

19Electrical Grounding

The heater detected an electrical short in one of its components.

Difficulty
Technician
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Rinnai code 19

  1. Make sure the heater is plugged into a properly grounded outlet
  2. Reset: turn off hot water taps and press ON/OFF on the controller twice
  3. If the code comes back, call a licensed Rinnai service provider

What 19 means on your Rinnai

Rinnai explains that a code 19 right after water starts flowing means an electrical short in one of the heater's components: a wiring harness, the water flow control, the bypass valve or another part of the DC circuit.

What a technician will check: unplugging components one at a time and cycling the heater; if it runs normally three times with a part unplugged, that part has the short.

Likely causes

  • Shorted wiring harness
  • Shorted water flow control or bypass valve
  • Another DC component shorted

Sources