How to fix Rinnai code 63
- Make sure the cold water inlet and hot water outlet valves are open
- Run hot water at the fixtures until you no longer hear air in the lines
- Check that the recirculation pump has power
- Reset: turn off hot water taps and press ON/OFF on the controller twice
- If the code comes back, call a licensed Rinnai service provider
What 63 means on your Rinnai
Code 63 only applies when recirculation is set up, either crossover (comfort valve) or a dedicated return line.
Rinnai's checks include clearing the inlet and bypass filters (water off and heater drained first), opening the inlet and outlet valves, purging air from the recirculation line, and confirming the pump gets 120 VAC.
What a technician will check: the recirculation DIP switches (Non-SENSEI) or Parameter 04 (SENSEI), the bypass plug and filter for crossover mode, and that a dedicated return line isn't longer than allowed.
Likely causes
- Clogged inlet or bypass filter
- Air trapped in the recirculation line
- Closed inlet or outlet valve
- Recirculation pump not getting power
- Wrong recirculation setting