Rinnai Gas Valve & Burner Codes (15, 18, 22, 31, 57, 71, 72, 73)

These codes involve the gas valve, venturi control, flame rod, thermocouple or burner overheat switch. All of them are gas-system repairs for a licensed technician; the only homeowner step is a reset.

Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

15Venturi Control

The venturi control device that adjusts the air/gas mix isn't responding.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 015 · Confirmed by manufacturer · checked 2026-11-21

18Gas Valve Adjustment Limit

The gas valve reached its adjustment limit. Gas type and gas valve parameters need checking.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 018 · Confirmed by manufacturer · checked 2026-11-21

22Gas Valve Adjustment

The gas valve's position switch or parameters aren't correct.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 022 · Confirmed by manufacturer · checked 2026-11-21

31Burner Thermocouple

The burner thermocouple reading is out of range, which can mean the burner is over-firing.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 031 · Confirmed by manufacturer · checked 2026-11-21

57Burner Overheat Bi-metal Switch

The burner overheat switch tripped or its circuit is open.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 057 · Confirmed by manufacturer · checked 2026-11-21

71Gas Solenoid Valve

The gas solenoid valve circuit has a fault. A control-board DIP switch left ON also causes this code.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 071 · Confirmed by manufacturer · checked 2026-11-21

72Flame Rod Fault

The flame rod isn't sensing the flame properly, often from carbon build-up.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 072 · Confirmed by manufacturer · checked 2026-11-21

73Burner Thermocouple Fault

The burner thermocouple circuit has a fault.

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

Also shown as: 073 · Confirmed by manufacturer · checked 2026-11-21