16High Outgoing Water Temperature

Safety shutdown: water leaving the heater went above 203 °F (95 °C).

Difficulty
Technician
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Rinnai code 16

  1. Check the outside vent terminal for snow, leaves, nests or anything blocking it
  2. Reset: turn off hot water taps and press ON/OFF on the controller twice
  3. If the code comes back, call a licensed Rinnai service provider

What 16 means on your Rinnai

Code 16 is a high-temperature safety shutdown at 203 °F / 95 °C outlet water temperature.

What a technician will check: airflow around the vent terminal, fan operation and the check valve behind the fan, foreign material in the combustion chamber and exhaust, blockage in the heat exchanger, and the gas type setting. Rinnai lists the gas valve or fan assembly as the parts to replace if those checks pass.

Likely causes

  • Restricted airflow at the vent terminal
  • Combustion fan problem
  • Blocked heat exchanger
  • Debris in the combustion chamber or exhaust
  • Wrong gas type setting