How to fix Rinnai code 02
- Make sure every gas valve feeding the heater (at the heater and at the meter) is fully open
- On propane, check that the tank isn't empty
- Reset: turn off hot water taps and press ON/OFF on the controller twice
- If the code comes back, call a licensed Rinnai service provider
What 02 means on your Rinnai
Code 02 appears on Non-SENSEI models when freeze protection calls for the burner and it doesn't run. Rinnai's checks start with the gas supply: open valves, purged gas lines, correct inlet pressure and the correct gas type.
What a technician will check: inlet gas pressure against the rating plate with all gas appliances firing, that the gas type matches the heater, and the gas-type DIP switch on the control board.
Until it's fixed, the heater may be at risk of freezing. Keep power connected, because freeze protection needs electricity.
Likely causes
- Gas valve closed or gas supply off
- Low inlet gas pressure
- Wrong gas type setting
Sources
- Rinnai: Troubleshooting Tankless Water Heater Diagnostic Codes (doc. 100000652) manufacturer checked 2026-11-21
Spotted an error on this page? Report it and we'll re-check it against the manual.