02No Burner Operation During Freeze Protection

The heater tried to fire the burner to protect itself from freezing but couldn't, usually because gas isn't reaching it.

Difficulty
Moderate
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Rinnai code 02

  1. Make sure every gas valve feeding the heater (at the heater and at the meter) is fully open
  2. On propane, check that the tank isn't empty
  3. Reset: turn off hot water taps and press ON/OFF on the controller twice
  4. If the code comes back, call a licensed Rinnai service provider

What 02 means on your Rinnai

Code 02 appears on Non-SENSEI models when freeze protection calls for the burner and it doesn't run. Rinnai's checks start with the gas supply: open valves, purged gas lines, correct inlet pressure and the correct gas type.

What a technician will check: inlet gas pressure against the rating plate with all gas appliances firing, that the gas type matches the heater, and the gas-type DIP switch on the control board.

Until it's fixed, the heater may be at risk of freezing. Keep power connected, because freeze protection needs electricity.

Likely causes

  • Gas valve closed or gas supply off
  • Low inlet gas pressure
  • Wrong gas type setting