Rinnai Tankless Water Heater · SENSEI series · SENSEI RX/CX series · Non-SENSEI series

61Combustion Fan Motor

The combustion fan isn't running correctly.

Difficulty
Technician
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Rinnai code 61

  1. Reset: turn off hot water taps and press ON/OFF on the controller twice
  2. If the code comes back, call a licensed Rinnai service provider

What 61 means on your Rinnai

Code 61 means the control isn't seeing the fan motor run as expected.

What a technician will check, with power and gas off: the fan wiring back to the control board, that the blower wheel turns freely, debris in the fan housing, the check valve behind the fan on SENSEI models, and the motor winding resistance against the data sheet inside the front cover.

Likely causes

  • Loose or damaged fan wiring
  • Debris stopping the fan wheel
  • Stuck check valve behind the fan (SENSEI)
  • Failed fan motor

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.