| 02 | No Burner Operation During Freeze Protection | Confirmed by manufacturer |
| 03 | Power Interruption During Bath Fill | Confirmed by manufacturer |
| 05 | Bypass Flow Control Device | Confirmed by manufacturer |
| 07 | Circulation Flow Rate Below 2.1 GPM (RH180) | Confirmed by manufacturer |
| 10 | Air Supply or Exhaust Blockage, or Condensate Trap Full | Confirmed by manufacturer |
| 11 | No Ignition | Confirmed by manufacturer |
| 12 | Flame Failure | Confirmed by manufacturer |
| 13 | Combustion (RH180) | Confirmed by manufacturer |
| 14 | Thermal Fuse or Overheat Sensor | Confirmed by manufacturer |
| 15 | Venturi Control | Confirmed by manufacturer |
| 16 | High Outgoing Water Temperature | Confirmed by manufacturer |
| 17 | Venturi Blockage | Confirmed by manufacturer |
| 18 | Gas Valve Adjustment Limit | Confirmed by manufacturer |
| 19 | Electrical Grounding | Confirmed by manufacturer |
| 21 | Data Transfer Error | Confirmed by manufacturer |
| 22 | Gas Valve Adjustment | Confirmed by manufacturer |
| 25 | Condensate Pump Error or Clogged Drain (Accessory Pump) | Confirmed by manufacturer |
| 30 | Flammable Vapor Sensor (RH180) | Confirmed by manufacturer |
| 31 | Burner Thermocouple | Confirmed by manufacturer |
| 32 | Outgoing Water Temperature Thermistor | Confirmed by manufacturer |
| 33 | Heat Exchanger Thermistor | Confirmed by manufacturer |
| 34 | Combustion Air (Non-SENSEI) / Lime Detecting (SENSEI RX/CX) Thermistor | Confirmed by manufacturer |
| 35 | Tank Temperature Sensor | Confirmed by manufacturer |
| 38 | Exhaust Gas Temperature Sensor | Confirmed by manufacturer |
| 41 | Freeze Protection Sensor (Outdoor Models) | Confirmed by manufacturer |
| 51 | Inlet Water Temperature Thermistor | Confirmed by manufacturer |
| 52 | Gas Valve | Confirmed by manufacturer |
| 54 | High Exhaust Gas Temperature | Confirmed by manufacturer |
| 57 | Burner Overheat Bi-metal Switch | Confirmed by manufacturer |
| 58 | Secondary Heat Exchanger Sensor | Confirmed by manufacturer |
| 61 | Combustion Fan Motor | Confirmed by manufacturer |
| 63 | Recirculation Low Flow | Confirmed by manufacturer |
| 65 | Water Flow Control Device | Confirmed by manufacturer |
| 66 | Bypass Flow Servo | Confirmed by manufacturer |
| 70 | PC Board Fault | Confirmed by manufacturer |
| 71 | Gas Solenoid Valve | Confirmed by manufacturer |
| 72 | Flame Rod Fault | Confirmed by manufacturer |
| 73 | Burner Thermocouple Fault | Confirmed by manufacturer |
| 79 | Water Leakage Detected | Confirmed by manufacturer |
| FE | Flammable Vapors Detected (RH180) | Confirmed by manufacturer |
| FF | Maintenance Has Been Performed | Confirmed by manufacturer |
| LC | Scale Build-up in Heat Exchanger | Confirmed by manufacturer |
| SE | Cascade Diagnostic Display | Confirmed by manufacturer |
| SS | Service Soon Alert | Confirmed by manufacturer |