Rinnai Tankless Water Heater · SENSEI series · SENSEI RX/CX series · Non-SENSEI series

54High Exhaust Gas Temperature

The exhaust stayed too hot. Above 163 °F the heater lowers its firing rate; if it's still above 163 °F after 120 seconds, it shuts down with code 54.

Difficulty
Technician
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Rinnai code 54

  1. Check the outside vent terminal for snow, leaves, nests or anything blocking it
  2. Reset: turn off hot water taps and press ON/OFF on the controller twice
  3. If the code comes back, call a licensed Rinnai service provider

What 54 means on your Rinnai

Rinnai describes code 54 precisely: the heater reduces input when exhaust passes 163 °F, and shuts down if it stays above that for 120 seconds.

What a technician will check: vent clearances and restrictions, vent length, gas type, that inlet water isn't above 160 °F, and hot spots on the heat exchanger. Hot spots mean scale inside, and Rinnai's fix is flushing the heat exchanger (with four gallons of vinegar) per the owner's manual.

Likely causes

  • Vent terminal clearances or restrictions
  • Vent too long or not to spec
  • Wrong gas type
  • Inlet water hotter than 160 °F
  • Scale build-up in the heat exchanger

Parts and supplies for this fix

  • Tankless water heater flushing kit (pump + hoses)Check price