Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.
How to fix Rheem code A011
- Make sure the gas shut-off valve to the heater is fully open
- Check that other gas appliances work; if not, contact your gas utility
- If the code is still shown, note it and call a qualified service technician
What A011 means on your Rheem
Rheem's service manual says the heater attempts ignition 10 times (with a post-purge every 3 tries) before showing A011.
What a technician will check: gas supply pressure (natural gas 4.0–10.5 in. w.c., propane 8.0–13.0 in. w.c.), pressure drop when other gas appliances run, the regulator, and the igniter and flame rod.
Likely causes
- Gas supply valve closed or low gas pressure
- Igniter or flame rod problem
- Gas filter or supply issue
Sources
- Rheem IKONIC (RTGH-S) Tankless Technical Training and Service Manual AP23209 Rev 03, Error Code Diagnostics service manual checked 2026-11-21
Spotted an error on this page? Report it and we'll re-check it against the manual.