Rheem Tankless Water Heater · RTGH-S condensing tankless (IKONIC)

A090Detected Blockage in Venting

The heater detected a blockage in its venting.

Difficulty
Moderate
Safety
Use caution
Source
From a service manual
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Rheem code A090

  1. Check the outside vent terminations for snow, leaves, nests or other blockages
  2. If the code is still shown, note it and call a qualified service technician

What A090 means on your Rheem

Rheem lists venting, the air filter and gas inlet pressure as the diagnostic check items for A090.

What a technician will check: the full vent run, the heater's air filter, and gas supply pressure (natural gas 4.0–10.5 in. w.c., propane 8.0–13.0 in. w.c.).

Likely causes

  • Blocked or restricted vent
  • Dirty air filter
  • Low gas inlet pressure

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.