Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.
How to fix Rheem code A012
- Make sure the gas shut-off valve to the heater is fully open
- If the code is still shown, note it and call a qualified service technician
What A012 means on your Rheem
Rheem's service manual: when flame is lost during combustion the heater shuts off fuel and retries, counting flame-loss incidents; after 15 in a row it shows A012.
What a technician will check: the gas filter at the heater's gas connection (cleaning it if blocked), gas pressure under load, and the flame rod.
Likely causes
- Blocked gas filter at the gas connection
- Gas supply pressure drop
- Flame rod problem
Sources
- Rheem IKONIC (RTGH-S) Tankless Technical Training and Service Manual AP23209 Rev 03, Error Code Diagnostics service manual checked 2026-11-21