Goodman Furnace · GM9S single-stage 92%/96% furnaces

EE3Open High Limit Switch

The furnace overheated and the high limit switch opened, usually because not enough air is moving across the heat exchanger.

Difficulty
Easy
Safety
Use caution
Source
From a service manual
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Goodman code EE3

  1. Replace or clean the furnace air filter and make sure supply and return vents are open
  2. Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
  3. If the code returns, call a licensed HVAC technician

What EE3 means on your Goodman

EE3 means the high limit opened. Goodman's troubleshooting chart points first to insufficient conditioned air over the heat exchanger: blocked filters, restrictive ductwork, wrong circulator blower speed, or a failed blower motor.

A clogged filter is the most common cause and the easiest fix. If a clean filter doesn't stop it, a technician should check blower speed, the motor and the limit wiring. Repeated overheating is hard on the heat exchanger, so don't ignore it.

Likely causes

  • Dirty air filter
  • Closed or blocked vents and restrictive ductwork
  • Blower speed too low or failed blower motor
  • Loose wiring in the limit circuit

Parts and supplies for this fix

We may earn a commission from purchases made through these links. Confirm the part matches your exact model number before buying.

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.