Goodman Furnace · GM9S single-stage 92%/96% furnaces

EE1Pressure Switch Stuck Closed

The pressure switch reads closed before the inducer fan starts, so the furnace won't begin a heating cycle.

Difficulty
Technician
Safety
Call a pro
Source
From a service manual
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Goodman code EE1

  1. Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
  2. If the code returns, call a licensed HVAC technician

What EE1 means on your Goodman

The control checks that the pressure switch is open before it starts the draft inducer. If it's already closed, the furnace waits until the fault clears. Goodman lists a faulty pressure switch or wiring as the probable causes, so this is a technician repair.

Likely causes

  • Faulty pressure switch
  • Wiring fault

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.