Goodman Furnace · GMVC96 two-stage variable-speed furnaces

E6Low Flame Sense Signal

The furnace keeps running but the flame sensor signal has dropped below the specified level.

Difficulty
Moderate
Safety
Use caution
Source
From a service manual
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Goodman code E6

  1. Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
  2. Have a technician clean or reposition the flame sensor and check gas pressure

What E6 means on your Goodman

Goodman's probable causes: a coated or oxidized sensor, a sensor positioned incorrectly in the flame, or a lazy burner flame from improper gas pressure or combustion air.

Likely causes

  • Coated or oxidized flame sensor
  • Sensor positioned incorrectly
  • Lazy flame from incorrect gas pressure or combustion air

Parts and supplies for this fix

We may earn a commission from purchases made through these links. Confirm the part matches your exact model number before buying.

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.