Safety: Turn the power off before any checks inside the unit.
How to fix Goodman code EE2
- Check the PVC intake and exhaust pipes outside for snow, ice, nests or debris
- Make sure the condensate drain line and trap aren't clogged
- Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
- If the code returns, call a licensed HVAC technician
What EE2 means on your Goodman
EE2 is one of the most common winter codes on high-efficiency furnaces. The pressure switch proves the inducer is moving combustion air; if the intake or exhaust is blocked, or condensate backs up, it won't close.
Goodman lists disconnected pressure switch hose, a faulty switch or wiring, and restricted air intake or flue piping as probable causes. Snow drifts over the outdoor pipes are a frequent culprit.
Likely causes
- Blocked intake or exhaust pipe
- Clogged condensate drain
- Disconnected or kinked pressure switch hose
- Faulty pressure switch or inducer
Sources
- Goodman GM9S92/GM9S96/GC9S96 Service and Troubleshooting manual RS6612022 (July 2021) service manual checked 2026-11-21