Goodman Furnace · GM9S single-stage 92%/96% furnaces

EE0Lockout Due to Excessive Retries or Recycles

The furnace tried to light several times without establishing a flame and locked itself out.

Difficulty
Technician
Safety
Call a pro
Source
From a service manual
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Goodman code EE0

  1. Make sure the gas valve to the furnace is on
  2. Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
  3. If the code returns, call a licensed HVAC technician

What EE0 means on your Goodman

EE0 is Goodman's ignition lockout on GM9S single-stage furnaces: the control ran out of ignition retries or recycles and stopped trying.

Goodman's two-stage manual describes the same lockout logic: the control cycles the gas valve three times, then locks out. It resets automatically after one hour, or when the thermostat is turned off for 5–20 seconds and back on. A furnace that keeps needing resets has a problem that should be fixed.

What a technician will check: gas supply and pressure, the igniter, the flame sensor (cleaning it if coated), and the pressure switch and venting.

Likely causes

  • Gas supply off or interrupted
  • Dirty or poorly positioned flame sensor
  • Igniter problem
  • Venting or pressure switch issue

Parts and supplies for this fix

We may earn a commission from purchases made through these links. Confirm the part matches your exact model number before buying.

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.