Goodman Furnace · GMVC96 two-stage variable-speed furnaces

E0System Lockout

No flame was sensed after three ignition attempts, so the furnace locked out.

Difficulty
Technician
Safety
Call a pro
Source
From a service manual
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Goodman code E0

  1. Make sure the gas valve to the furnace is on
  2. Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
  3. If the code returns, call a licensed HVAC technician

What E0 means on your Goodman

Goodman describes the sequence: if no flame is sensed after the gas valve opens, the control purges and retries; after three attempts it locks out with E0.

Reset by turning the thermostat off for more than 5 and less than 20 seconds and back on, or by switching off power to the furnace for at least 5 seconds. The control also resets itself one hour after a lockout. If you have to reset it often, there's a problem that should be corrected.

Likely causes

  • Gas supply off or low
  • Dirty flame sensor
  • Igniter problem
  • Venting or pressure switch issue

Parts and supplies for this fix

We may earn a commission from purchases made through these links. Confirm the part matches your exact model number before buying.

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.