Safety: Turn the power off before any checks inside the unit.
How to fix Goodman code E9
- Check the PVC intake and exhaust pipes outside for snow, ice, nests or debris
- Make sure the condensate drain line and trap aren't clogged
- Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
- If the code returns, call a licensed HVAC technician
What E9 means on your Goodman
Goodman: check for a blocked or pinched hose, a blocked flue or inlet air pipe, a blocked drain, a weak induced draft blower, or a malfunctioning pressure switch. The display shows E9 followed by a pause.
Likely causes
- Blocked or pinched pressure switch hose
- Blocked flue or intake pipe
- Blocked drain
- Weak inducer or faulty switch
Sources
- Goodman GMVC96/GCVC96 Service Instructions RS6612010r6 (November 2017) service manual checked 2026-11-21