Goodman Furnace · GMVC96 two-stage variable-speed furnaces

E9High Stage Pressure Switch Stuck Open

The high-stage pressure switch won't close, often from a blocked hose, flue, intake or drain.

Difficulty
Moderate
Safety
Use caution
Source
From a service manual
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Goodman code E9

  1. Check the PVC intake and exhaust pipes outside for snow, ice, nests or debris
  2. Make sure the condensate drain line and trap aren't clogged
  3. Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
  4. If the code returns, call a licensed HVAC technician

What E9 means on your Goodman

Goodman: check for a blocked or pinched hose, a blocked flue or inlet air pipe, a blocked drain, a weak induced draft blower, or a malfunctioning pressure switch. The display shows E9 followed by a pause.

Likely causes

  • Blocked or pinched pressure switch hose
  • Blocked flue or intake pipe
  • Blocked drain
  • Weak inducer or faulty switch