Goodman Furnace · GMVC96 two-stage variable-speed furnaces

E2Low Stage Pressure Switch Stuck Open

The low-stage pressure switch didn't close within 5 minutes of the inducer starting, so the furnace went into a 1-hour lockout.

Difficulty
Moderate
Safety
Use caution
Source
From a service manual
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Goodman code E2

  1. Check the PVC intake and exhaust pipes outside for snow, ice, nests or debris
  2. Make sure the condensate drain line and trap aren't clogged
  3. Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
  4. If the code returns, call a licensed HVAC technician

What E2 means on your Goodman

Goodman's probable causes for E2: a disconnected hose to the pressure switch, a faulty pressure switch or wiring, or restricted air intake or flue piping. The control retries automatically after its 1-hour lockout.

Likely causes

  • Disconnected pressure switch hose
  • Restricted air intake or flue piping
  • Faulty pressure switch or wiring