Safety: Turn the power off before any checks inside the unit.
How to fix Goodman code E2
- Check the PVC intake and exhaust pipes outside for snow, ice, nests or debris
- Make sure the condensate drain line and trap aren't clogged
- Reset: turn the thermostat off for 5–20 seconds and back on, or switch off power to the furnace for at least 5 seconds
- If the code returns, call a licensed HVAC technician
What E2 means on your Goodman
Goodman's probable causes for E2: a disconnected hose to the pressure switch, a faulty pressure switch or wiring, or restricted air intake or flue piping. The control retries automatically after its 1-hour lockout.
Likely causes
- Disconnected pressure switch hose
- Restricted air intake or flue piping
- Faulty pressure switch or wiring
Sources
- Goodman GMVC96/GCVC96 Service Instructions RS6612010r6 (November 2017) service manual checked 2026-11-21