E047Exhaust Thermostat: Thermistor Open or Short Circuit
The exhaust temperature sensor is reading as open or short-circuited, so the heater can't monitor flue temperature.
- Press the Back button on the front panel to reset the water heater
- If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician
Also shown as: 047, E-047 · Confirmed by manufacturer · checked 2026-11-20
E407Hot Water Outlet: Thermistor Open or Short Circuit
The hot water outlet temperature sensor is reading as open or short-circuited.
- Press the Back button on the front panel to reset the water heater
- If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician
Also shown as: 407, E-407 · Confirmed by manufacturer · checked 2026-11-20
E421Cold Water Inlet 1: Thermistor Open or Short Circuit
Cold water inlet temperature sensor 1 is reading as open or short-circuited.
- Press the Back button on the front panel to reset the water heater
- If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician
Also shown as: 421, E-421 · Confirmed by manufacturer · checked 2026-11-20
E432Cold Water Inlet 2: Thermistor Open or Short Circuit
Cold water inlet temperature sensor 2 is reading as open or short-circuited.
- Press the Back button on the front panel to reset the water heater
- If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician
Also shown as: 432, E-432 · Confirmed by manufacturer · checked 2026-11-20
E441Hot Water Inlet 2: Thermistor Open or Short Circuit
Hot water inlet temperature sensor 2 is reading as open or short-circuited.
- Press the Back button on the front panel to reset the water heater
- If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician
Also shown as: 441, E-441 · Confirmed by manufacturer · checked 2026-11-20
E740Abnormal Operation: Outdoor Temperature Sensor (If an Air Handler Is Installed)
On systems with an air handler (AHU), the outdoor temperature sensor is not reporting normally.
- Press the Back button on the front panel to reset the water heater
- If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician
Also shown as: 740, E-740 · Confirmed by manufacturer · checked 2026-11-20