Navien Tankless Water Heater · NPE-A2 series · NPE-S2 series

Navien Temperature Sensor Error Codes (E047, E407, E421, E432, E441, E740)

These codes mean one of the heater's temperature sensors (thermistors) is reading as open or short-circuited, so the control can't trust that temperature. Navien's manual gives the same remedy for all of them: contact technical support. A failed sensor or loose sensor wiring is diagnosed and replaced by a technician.

Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

E047Exhaust Thermostat: Thermistor Open or Short Circuit

The exhaust temperature sensor is reading as open or short-circuited, so the heater can't monitor flue temperature.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 047, E-047 · Confirmed by manufacturer · checked 2026-11-20

E407Hot Water Outlet: Thermistor Open or Short Circuit

The hot water outlet temperature sensor is reading as open or short-circuited.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 407, E-407 · Confirmed by manufacturer · checked 2026-11-20

E421Cold Water Inlet 1: Thermistor Open or Short Circuit

Cold water inlet temperature sensor 1 is reading as open or short-circuited.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 421, E-421 · Confirmed by manufacturer · checked 2026-11-20

E432Cold Water Inlet 2: Thermistor Open or Short Circuit

Cold water inlet temperature sensor 2 is reading as open or short-circuited.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 432, E-432 · Confirmed by manufacturer · checked 2026-11-20

E441Hot Water Inlet 2: Thermistor Open or Short Circuit

Hot water inlet temperature sensor 2 is reading as open or short-circuited.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 441, E-441 · Confirmed by manufacturer · checked 2026-11-20

E740Abnormal Operation: Outdoor Temperature Sensor (If an Air Handler Is Installed)

On systems with an air handler (AHU), the outdoor temperature sensor is not reporting normally.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 740, E-740 · Confirmed by manufacturer · checked 2026-11-20