Navien Tankless Water Heater · NPE-A2 series · NPE-S2 series

Navien Control, Panel & Memory Error Codes (E517, E593, E594, E615, E736, E782)

These codes point to the heater's electronics: the DIP switch configuration, the front panel, the control's memory, or communication between boards or cascaded units. None of them have a homeowner fix in Navien's manual beyond resetting the unit; a technician should diagnose them.

Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

E517Abnormal Operation: DIP Switch Setting

The heater's DIP switch configuration is not valid.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 517, E-517 · Confirmed by manufacturer · checked 2026-11-20

E593Abnormal Operation: Front Panel Key

A front panel button is reporting a fault, for example a stuck key.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 593, E-593 · Confirmed by manufacturer · checked 2026-11-20

E594Abnormal Operation: EEPROM

The control's memory chip (EEPROM) reported a fault.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 594, E-594 · Confirmed by manufacturer · checked 2026-11-20

E615Abnormal Operation: Input and Memory

The control reported an input or memory fault.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 615, E-615 · Confirmed by manufacturer · checked 2026-11-20

E736Abnormal Operation: Cascade Communication

In a multi-unit (cascade) installation, the heaters can't communicate with each other.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 736, E-736 · Confirmed by manufacturer · checked 2026-11-20

E782Abnormal Operation: Main Panel Communication

The front panel and the main control can't communicate.

  1. Press the Back button on the front panel to reset the water heater
  2. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

Also shown as: 782, E-782 · Confirmed by manufacturer · checked 2026-11-20