Navien Tankless Water Heater · NPE-A2 series · NPE-S2 series

E515Abnormal Operation: PCB

The main circuit board (PCB) reported a fault.

Difficulty
Technician
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-20
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Navien code E515

  1. Make sure the power cord is plugged into a properly grounded outlet
  2. Press the Back button on the front panel to reset the water heater
  3. If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician

What E515 means on your Navien

E515 means the main circuit board (PCB) reported a fault. The manual's remedy is to make sure the power cord is properly grounded, since poor grounding can cause electronic faults.

If the outlet is grounded and the code returns after a reset, the control board needs a technician.

Likely causes

  • Improper electrical grounding
  • Circuit board fault (technician diagnosis)

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.