Safety: Turn the power off before any checks inside the unit.
How to fix Navien code E438
- Check that the circulation pump is operating properly
- Press the Back button on the front panel to reset the water heater
- If the code comes back: contact Navien Technical Support (1-800-519-8794) or a licensed technician
What E438 means on your Navien
E438 only applies when the heater is connected to an air handler (AHU) for space heating. It means the circulation pump isn't operating properly. Check that the pump has power and is running; if it isn't, the pump or its wiring needs a technician.
Likely causes
- Circulation pump not running
Sources
- Navien NPE-2 User's Information Manual v1.0 (2020), section 5.2, pp. 17-18 manufacturer checked 2026-11-20
Spotted an error on this page? Report it and we'll re-check it against the manual.