Carrier Furnace · 59SC5B single-stage condensing furnaces

33Limit Circuit Fault

A limit or flame rollout switch is open. The blower runs for at least 4 minutes; if it stays open over 3 minutes the code becomes 13.

Difficulty
Easy
Safety
Use caution
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Carrier code 33

  1. Replace or clean the furnace air filter and open any closed supply or return vents
  2. Check the intake and exhaust (vent) pipes outside for snow, ice, nests or blockages
  3. Reset: switch the furnace power off for a few seconds and back on
  4. If the code returns, call a licensed HVAC technician

What 33 means on your Carrier

Code 33 is usually overheating from poor airflow. Carrier's checklist starts with a dirty filter or restricted duct system, then vent sizing and restrictions, the blower motor and wheel, excessive wind, and the switch itself.

Carrier notes the flame rollout switch requires a manual reset. If it was the rollout switch, have a technician find out why before resetting it again.

Count the flashes: the first digit is the number of short flashes, the second the number of long flashes.

Likely causes

  • Dirty filter or restricted duct system
  • Restricted or undersized vent
  • Defective blower motor or loose blower wheel
  • Excessive wind
  • Inadequate combustion air (rollout switch)
  • Defective switch or connections

Parts and supplies for this fix

We may earn a commission from purchases made through these links. Confirm the part matches your exact model number before buying.

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.