How to fix Carrier code 13
- Replace or clean the furnace air filter and open any closed supply or return vents
- Check the intake and exhaust (vent) pipes outside for snow, ice, nests or blockages
- Reset: switch the furnace power off for a few seconds and back on
- If the code returns, call a licensed HVAC technician
What 13 means on your Carrier
Code 13 is the lockout version of code 33: a limit or rollout switch has been open for more than 3 minutes. Carrier says the control auto-resets after three hours and points to code 33's checklist.
Start with the filter, the most common cause of overheating. If a flame rollout switch tripped, it needs a manual reset and an inspection, because rollout can mean combustion air or venting problems.
Count the flashes: the first digit is the number of short flashes, the second the number of long flashes.
Likely causes
- Dirty filter or restricted ducts
- Restricted or undersized vent
- Blower motor or blower wheel problem
- Flame rollout from inadequate combustion air
- Defective switch or connections
Parts and supplies for this fix
- Furnace air filter (check your filter size)Check price
We may earn a commission from purchases made through these links. Confirm the part matches your exact model number before buying.
Sources
- Carrier 59SC5B Installation, Start-up, Operating & Service Instructions (59SC5B-05SI), service label manufacturer checked 2026-11-21
Spotted an error on this page? Report it and we'll re-check it against the manual.