A limit or flame rollout switch stayed open longer than 3 minutes, so the furnace locked out. It auto-resets after three hours.

Difficulty
Moderate
Safety
Use caution
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Carrier code 13

  1. Replace or clean the furnace air filter and open any closed supply or return vents
  2. Check the intake and exhaust (vent) pipes outside for snow, ice, nests or blockages
  3. Reset: switch the furnace power off for a few seconds and back on
  4. If the code returns, call a licensed HVAC technician

What 13 means on your Carrier

Code 13 is the lockout version of code 33: a limit or rollout switch has been open for more than 3 minutes. Carrier says the control auto-resets after three hours and points to code 33's checklist.

Start with the filter, the most common cause of overheating. If a flame rollout switch tripped, it needs a manual reset and an inspection, because rollout can mean combustion air or venting problems.

Count the flashes: the first digit is the number of short flashes, the second the number of long flashes.

Likely causes

  • Dirty filter or restricted ducts
  • Restricted or undersized vent
  • Blower motor or blower wheel problem
  • Flame rollout from inadequate combustion air
  • Defective switch or connections