Carrier Furnace · 59SC5B single-stage condensing furnaces

24Secondary Voltage Fuse Is Open

The 24-volt fuse on the control blew, so the furnace and thermostat lose low-voltage power.

Difficulty
Technician
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Carrier code 24

  1. Turn off power to the furnace
  2. If the code returns, call a licensed HVAC technician

What 24 means on your Carrier

Carrier's label: check for a short circuit in the secondary (24 VAC) wiring. The manual also notes the control shows code 24 when the fuse needs replacing. A new fuse will blow again unless the short is found, often in thermostat wire damaged during other work or in the outdoor unit's wiring.

Count the flashes: the first digit is the number of short flashes, the second the number of long flashes.

Likely causes

  • Short circuit in the 24 VAC (thermostat or outdoor unit) wiring

Sources