Carrier Furnace · 59SC5B single-stage condensing furnaces

31High Pressure Switch Did Not Close or Reopened

The high-stage pressure switch didn't close (or reopened). After three tries the furnace locks out for 3 hours.

Difficulty
Moderate
Safety
Use caution
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Carrier code 31

  1. Check the intake and exhaust (vent) pipes outside for snow, ice, nests or blockages
  2. Make sure the condensate drain isn't clogged
  3. Reset: switch the furnace power off for a few seconds and back on
  4. If the code returns, call a licensed HVAC technician

What 31 means on your Carrier

Code 31 is one of the most common Carrier codes on condensing furnaces. Carrier's checklist includes restricted condensate drainage, disconnected or obstructed pressure tubing, inadequate combustion air, vent sizing, low inducer voltage, a defective switch, and low inlet gas pressure where a low gas pressure switch is fitted.

Winter tip: snow over the vent terminals and frozen or clogged condensate lines are frequent causes.

Count the flashes: the first digit is the number of short flashes, the second the number of long flashes.

Likely causes

  • Restricted or blocked condensate drainage
  • Disconnected or obstructed pressure tubing
  • Inadequate combustion air or vent sizing
  • Low inducer voltage or defective pressure switch
  • Low inlet gas pressure (if a low gas pressure switch is used)