Carrier Furnace · 59SC5B single-stage condensing furnaces

32Low Pressure Switch Did Not Close or Reopened

The low-stage pressure switch stayed open longer than five minutes, so the inducer shuts off for 15 minutes before retrying.

Difficulty
Moderate
Safety
Use caution
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Carrier code 32

  1. Check the intake and exhaust (vent) pipes outside for snow, ice, nests or blockages
  2. Make sure the condensate drain isn't clogged
  3. Reset: switch the furnace power off for a few seconds and back on
  4. If the code returns, call a licensed HVAC technician

What 32 means on your Carrier

Carrier says to troubleshoot code 32 the same way as code 31: condensate drainage, pressure tubing, combustion air, venting and the switch itself.

Count the flashes: the first digit is the number of short flashes, the second the number of long flashes.

Likely causes

  • Restricted condensate drainage
  • Obstructed pressure tubing
  • Vent or combustion air problem
  • Defective pressure switch