Carrier Furnace · 59SC5B single-stage condensing furnaces

14Ignition Lockout

The furnace failed to prove ignition after repeated tries and locked out. It auto-resets after three hours.

Difficulty
Technician
Safety
Call a pro
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

How to fix Carrier code 14

  1. Make sure the manual gas shut-off valve to the furnace is on
  2. Reset: switch the furnace power off for a few seconds and back on
  3. If the code returns, call a licensed HVAC technician

What 14 means on your Carrier

Code 14 follows repeated code 34 failures: after three more tries, the control locks out. Carrier says it auto-resets after three hours and refers to code 34's checklist (flame sensor, gas valve, gas pressure, igniter).

If you smell gas, don't reset it; leave and call your gas supplier.

Count the flashes: the first digit is the number of short flashes, the second the number of long flashes.

Likely causes

  • Gas valve or manual shut-off off
  • Dirty flame sensor
  • Low inlet gas pressure
  • Defective hot surface igniter

Parts and supplies for this fix

We may earn a commission from purchases made through these links. Confirm the part matches your exact model number before buying.

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.