Navien Combi Boiler · NCB-H combi-boilers

E110Exhaust Blockage

The boiler detected a blocked exhaust or restricted air intake.

Difficulty
Moderate
Safety
Use caution
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Navien code E110

  1. Check that the exhaust pipe and outside vent terminal are free of obstructions (snow, leaves, nests)
  2. Clean the air intake filter (Navien recommends every 3–4 months)
  3. Reset the boiler: press the Back button on the front panel
  4. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

What E110 means on your Navien

Navien's remedies for E110 are making sure the exhaust pipe is free of obstructions and cleaning the air intake filter. Snow and ice around the vent terminals are a common winter cause.

Never operate the boiler with damaged or disconnected venting.

Likely causes

  • Obstructed exhaust pipe or vent terminal
  • Dirty air intake filter

Parts and supplies for this fix