E004False Flame
The boiler sensed a flame when none should be present and shut down for safety.
- Make sure the power cord is plugged into a properly grounded outlet
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 004, E-004 · Confirmed by manufacturer · checked 2026-11-21
E020Abnormal Gas Control Valve
The gas control valve isn't operating normally.
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 020, E-020 · Confirmed by manufacturer · checked 2026-11-21
E030Exhaust Overheat
The exhaust temperature got too high.
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 030, E-030 · Confirmed by manufacturer · checked 2026-11-21
E031Burner Overheat
The burner area overheated.
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 031, E-031 · Confirmed by manufacturer · checked 2026-11-21
E123Abnormal Fan Motor Blower
The fan motor blower isn't operating normally.
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 123, E-123 · Confirmed by manufacturer · checked 2026-11-21
E434Abnormal Water Adjust Valve
The water adjustment valve isn't operating normally.
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 434, E-434 · Confirmed by manufacturer · checked 2026-11-21
E439No Domestic Water Flow Detected
The boiler isn't detecting domestic hot water flow when it expects to.
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 439, E-439 · Confirmed by manufacturer · checked 2026-11-21
E445Abnormal Mixing Valve
The mixing valve isn't operating normally.
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 445, E-445 · Confirmed by manufacturer · checked 2026-11-21
E773Improper Gas Type Detected
The boiler detected a different gas type than it's set up for.
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 773, E-773 · Confirmed by manufacturer · checked 2026-11-21
E788Incorrect Gas Type Setting
The gas type setting doesn't match the supplied gas.
- Have a qualified installer check the supplied gas type and match the gas type setting on the PCB DIP switch
- Reset the boiler: press the Back button on the front panel
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
Also shown as: 788, E-788 · Confirmed by manufacturer · checked 2026-11-21