How to fix Navien code E016
- Turn the boiler off for at least 30 minutes, then restart it
- Flush the heat exchanger (see the manual)
- If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)
What E016 means on your Navien
Navien's remedies for E016 are to turn the system off for at least 30 minutes and restart, then flush the heat exchanger.
Flushing an NCB-H needs flush valves on the near-boiler piping (included with the Navien Manifold System), a 5-gallon bucket, diluted cleaning solution and a circulation pump. Navien calls it "a somewhat complicated procedure": if you're unsure, have a technician do it.
Likely causes
- Scale build-up in the heat exchanger
- Restricted water flow
Parts and supplies for this fix
- Boiler/tankless flushing kit (pump + hoses)Check price
We may earn a commission from purchases made through these links. Confirm the part matches your exact model number before buying.
Sources
- Navien NCB-H User's Information Manual v1.0 (Jan 2025), section 5.2, pp. 25-26 manufacturer checked 2026-11-21
Spotted an error on this page? Report it and we'll re-check it against the manual.