Navien Combi Boiler · NCB-H combi-boilers

E777Low Water Cutoff Activated

The low water cutoff (LWCO) tripped because the system water level is too low.

Difficulty
Moderate
Safety
Use caution
Source
Confirmed by manufacturer
Last checked
2026-11-21
Safety: Turn the power off before any checks inside the unit.

How to fix Navien code E777

  1. Check the LWCO wiring connection
  2. Make sure the system water level is appropriate
  3. Add make-up water to the system if necessary
  4. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

What E777 means on your Navien

Navien's actions for E777 are checking the low water cutoff wiring, confirming the system water level, and adding make-up water if needed.

The manual says the system's cold fill pressure must be at least 12 psi. If you keep having to add water, the system may have a leak, so have it checked.

Likely causes

  • Low water in the heating system
  • LWCO wiring problem