Navien Combi Boiler · NCB-H combi-boilers

Navien Boiler Sensor Codes (E046, E047, E205, E218, E278, E279, E407, E421, E441)

These codes mean a temperature sensor on the NCB-H isn't reading or isn't detected: heat exchanger, exhaust, heating supply and return, external supply and return, and domestic hot water sensors. Navien's manual directs owners to contact technical support for each.

Safety: Involves gas, venting, refrigerant or electrical parts. Do the basic checks only, then call a licensed technician.

E046Heat Exchanger Thermistor

The heat exchanger temperature sensor isn't reading correctly.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 046, E-046 · Confirmed by manufacturer · checked 2026-11-21

E047Exhaust Thermistor

The exhaust temperature sensor isn't reading correctly.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 047, E-047 · Confirmed by manufacturer · checked 2026-11-21

E205Heating Supply Temperature Sensor

The heating supply water temperature sensor isn't reading correctly.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 205, E-205 · Confirmed by manufacturer · checked 2026-11-21

E218Heating Return Temperature Sensor

The heating return water temperature sensor isn't reading correctly.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 218, E-218 · Confirmed by manufacturer · checked 2026-11-21

E278External Supply Sensor Not Detected

An external supply sensor the boiler is set to use isn't detected.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 278, E-278 · Confirmed by manufacturer · checked 2026-11-21

E279External Return Sensor Not Detected

An external return sensor the boiler is set to use isn't detected.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 279, E-279 · Confirmed by manufacturer · checked 2026-11-21

E407Domestic Hot Water Outlet Sensor

The domestic hot water outlet temperature sensor isn't reading correctly.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 407, E-407 · Confirmed by manufacturer · checked 2026-11-21

E421Domestic Cold Water Inlet Sensor

The domestic cold water inlet temperature sensor isn't reading correctly.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 421, E-421 · Confirmed by manufacturer · checked 2026-11-21

E441Domestic Hot Water Outlet 2 Sensor

The second domestic hot water outlet sensor isn't reading correctly.

  1. Reset the boiler: press the Back button on the front panel
  2. If the code comes back: contact a licensed technician or Navien Technical Support (1-800-519-8794)

Also shown as: 441, E-441 · Confirmed by manufacturer · checked 2026-11-21

Sources

Spotted an error on this page? Report it and we'll re-check it against the manual.